What are the i3 features of FusionModule2000 V3.0 include? (Multiple choice)
Correct Answer: A,B,C Vote an answer
Which of the following air supply methods must have a reasonable raised floor height?
Correct Answer: C Vote an answer
Regarding the adjustable battery of UPS5000-E, when one battery is broken, at least () battery needs to be removed? Then set the corresponding number of battery cells on the monitoring panel.
Correct Answer: A Vote an answer
After the start-up and debugging of the air conditioner, the indoor temperature is in a reasonable state, and the suction pressure is not lower than () can be regarded as reasonable.
Correct Answer: A Vote an answer
Which of the following actions may be triggered after the high liquid level float of a Huawei chilled water precision air conditioner floats longer than the specified duration?
Correct Answer: B Vote an answer
A UPS system is configured with a single 50mm "2 (209A) cable, and the maximum current capacity allowed by the system is?
Correct Answer: D Vote an answer
After all historical alarms of the NetCol5000-A are deleted, the deletion operation is not logged.
Correct Answer: B Vote an answer
When the inspection, maintenance and repair of electrical installations are carried out in a non-stop work mode, warning signs or signs should be hung in the electrical installations and work area.
Correct Answer: A Vote an answer
The main unit of UPS5000-(DKVA power module) occupies a small area, saving the space of the computer room, and the area is only?
Correct Answer: A Vote an answer
Which of the following resources can be managed by the capacity management function of the Huawei NetEco management system? (Multiple choice)
Correct Answer: B,C,D Vote an answer
When the NETCOL5000-A air conditioner is turned on for commissioning, the possible cause of the exhaust high pressure alarm, which is incorrect?
Correct Answer: C Vote an answer
Commissioning NetCol5000-C drainage devices, after lifting the high float for 5 seconds, two water pumps start working, and the drain abnormal alarm is generated.
Correct Answer: A Vote an answer
Domains can be created in NETECO, such as campuses, buildings, computer rooms, containers, etc.
Correct Answer: A Vote an answer
The component that can realize RS486/CAN to FE interface conversion is ().
Correct Answer: C Vote an answer
When the UPS is in parallel, the input phase sequence of the main bypass of each UPS needs to be checked, and the output phase sequence of a single pair is not required.
Correct Answer: B Vote an answer