IBM 000-784 Actual Free Exam Questions & Community Discussion

  • Exam Code/Number: 000-784
  • Exam Name/Title: IBM PureFlex Technical Expert V1
  • Certification Provider: IBM
  • Corresponding Certification: IBM Certifed Systems Expert
  • Exam Questions: 70
  • Updated On: Jun 03, 2026
An x86 based PureFlex prospect currently has the following environment and requirements: The Fibre Channel adapter vendor they are standardized on is Emulex. The switch vendor they are standardized on is Brocade. Connectivity is 16Gbps. They need 4 ports per adapter. Which of the following combinations of switch and adapter is required for Fibre Channel connectivity?
Correct Answer: A Vote an answer
A client has purchased a Flex System with a Flex System Manager (FSM) and a p260 node. Which of the following is the most cost-effective procedure to install the VIO server?
Correct Answer: B Vote an answer
A Flex System prospect is evaluating IBM Flex System x86 compute nodes and the Flex System Manager (FSM). This prospect will adopt a dual-vendor strategy, and prefers to manage all vendors' ESXi hosts via a single console. Which of the following options best meets their management needs?
Correct Answer: D Vote an answer
The IBM Flex System Interoperability Guide is a handy reference document but its information is only as accurate as of its most recent publication date. Where would the technical expert find the latest complete information on supported FCoE configurations?
Correct Answer: C Vote an answer
A client has recently installed a Storwize V7000 storage system which they plan to connect to an IBM Flex solution.
However, they are experiencing some performance concerns with the existing installed storage and this is becoming a barrier to the solution sale.
The technical expert is provided with the following information and asked to suggest a possible cause and a solution while on site at the meeting.
Storage:
-Client is an ISP and offers "storage tiers of service" to their clients -Storwize V7000 with several disk expansion trays attached -Mixture of 200 GB SSD, 600 GB 10k rpm SAS drives and 2 TB NL-SAS drives installed -SSD and SAS drives in a single pool; Easy Tier enabled -NL-SAS drives in separate disk pool -Hosts are VMware Virtual machines.. (no applications mentioned) -Latency is high when viewed from the Storwize V7000 onboard performance monitor -Performance Monitor, STAT and Mon traces are provided in the exhibit




IBM 000-784 Exam
What course of action should the technical expert suggest given this initial information?
Correct Answer: A Vote an answer

Which question would help the technical expert determine whether it would be better to propose the SI4093 or the EN4093R?
Correct Answer: D Vote an answer

IBM 000-784 Exam
A client wants to provide a Flex solution that compares to a standard Power 750 running PowerVM and AIX. The client asks for a Flex System compute node with similar capacity and scalability for processor and memory. Which node should be discussed with the prospect?
Correct Answer: C Vote an answer
0
0
0
10