Network Appliance NS0-191 Actual Free Exam Questions & Community Discussion
You are creating a disk-partitioned root aggregate.
Which two rules are enforced automatically when accomplishing this task? (Choose two.)
Which two rules are enforced automatically when accomplishing this task? (Choose two.)
Correct Answer: A,C
Vote an answer
Click the Exhibit tab.

A customer receives the AutoSupport message shown below.
''(?] Sat Aug 23 13:00:27 PDT [hostname: env_rngr: callhome.c.fan.fru.fault:error] : Call home for CHASSIS FAN FRU FAILED: SysFan3 F2
(?] Sat Aug 23 13:00:32 PDT [hostname: env_mgr: monitor.chassisFan.ok:notice]: Chassis fan Sysfan3 F2 is ok"
The output of the sysconfig -a command is shown in the exhibit.
In this scenario, what would you do to solve this problem?

A customer receives the AutoSupport message shown below.
''(?] Sat Aug 23 13:00:27 PDT [hostname: env_rngr: callhome.c.fan.fru.fault:error] : Call home for CHASSIS FAN FRU FAILED: SysFan3 F2
(?] Sat Aug 23 13:00:32 PDT [hostname: env_mgr: monitor.chassisFan.ok:notice]: Chassis fan Sysfan3 F2 is ok"
The output of the sysconfig -a command is shown in the exhibit.
In this scenario, what would you do to solve this problem?
Correct Answer: C
Vote an answer
Click the Exhibit tab.

Your customer has recently migrated from their FAS3140 system running Data ONTAP 7.3.7 to a FAS2552 system running Data ONTAP 8.2.3 7-Mode through the head upgrade process. They are no longer receiving the weekly AutoSupport notifications and want to know why. The exhibit shows the AutoSupport options from the nodes that have the same settings.
In this scenario, which solution is correct?

Your customer has recently migrated from their FAS3140 system running Data ONTAP 7.3.7 to a FAS2552 system running Data ONTAP 8.2.3 7-Mode through the head upgrade process. They are no longer receiving the weekly AutoSupport notifications and want to know why. The exhibit shows the AutoSupport options from the nodes that have the same settings.
In this scenario, which solution is correct?
Correct Answer: A
Vote an answer
You log in to a SnapMirror destination to review the system. Which scanner would you expect to see running?
Correct Answer: A
Vote an answer
A customer cannot create a new volume from OnCommand System Manager.
Which two clustered Data ONTAP daemons would be at fault in this scenario? (Choose two.)
Which two clustered Data ONTAP daemons would be at fault in this scenario? (Choose two.)
Correct Answer: A,B
Vote an answer
You replaced the controller of an HA pair in a 4-node cluster running clustered Data ONTAP 8.3.1. You have gone through all hardware testing requirements before booting the system .
Which action is now required to boot the system successfully?
Which action is now required to boot the system successfully?
Correct Answer: B
Vote an answer