Huawei H13-629_V2.0 Actual Free Exam Questions & Community Discussion
Which of the following is NOT correct regarding the backup RMAN?
Correct Answer: C
Vote an answer
A customer RAID 5 fails in the OceanStor v3 storage array. After the engineer reclaims the RAID group tothe degraded state through commands, the RAID group tries to rebuild, but reconstruction failed many times, which of the following is correct (multiple choice).
Correct Answer: C,D
Vote an answer
In preparation for disaster recovery design, which of the following is correct?
Correct Answer: A
Vote an answer
In dual active disaster recovery solution architectures, the two FC switches will use the same domain ID after cascading to divide the zone.
Correct Answer: B
Vote an answer
When using lvm to create a mirrored logical volume, you should choose what kind of log file to save inorder not to impact performance and quickly recover from a single drive failure?
Correct Answer: A
Vote an answer
The OceanStor VIS6600T includes the following devices:
1. Host
2.VIS 6600T
3. Array
4. Fiber switch
Since there is a certain dependency between the above devices, the power-down needs to be performed accordingto a certain sequence. Which of the following power-off sequences is correct:
1. Host
2.VIS 6600T
3. Array
4. Fiber switch
Since there is a certain dependency between the above devices, the power-down needs to be performed accordingto a certain sequence. Which of the following power-off sequences is correct:
Correct Answer: C
Vote an answer
Which of the OceanStor V3 file system remote replication descriptions are correct? (Multiple choice.)
Correct Answer: A,C
Vote an answer
Using non-deduplication storage based on the disk library strategy, data recovery fails after the data life of the backup has expired. What is a reason for this?
Correct Answer: B
Vote an answer
Which remote replication description about the OceanStor V3 file system is correct? (Multiple choice.)
Correct Answer: C,D
Vote an answer
An N8000 file system can be used when offline command to query file system flag:
echo "8192B.p S" | fsdb -t vxfs / dev / vx / rdsk / sfsdg / sfsvol | grep flag Where sfsvol is the name of the file system and may appear as flsgs 0 mod 0 Clean 3c or flags 4000 mod clean
3c if flags last bit is 0, then the file system is set.
echo "8192B.p S" | fsdb -t vxfs / dev / vx / rdsk / sfsdg / sfsvol | grep flag Where sfsvol is the name of the file system and may appear as flsgs 0 mod 0 Clean 3c or flags 4000 mod clean
3c if flags last bit is 0, then the file system is set.
Correct Answer: B
Vote an answer
When formatting a newly created LUN on OceanStor V3, LUN formatting fails. Which of the followingconditions will cause this problem? (Multiple choice)
Correct Answer: B,D
Vote an answer
True or False, in a Huawei Oceanstro V3 smartVirtualization, eDevLUN and external LUNs are a one-to-onecorrespondence
Correct Answer: B
Vote an answer
True or false, with RedHat 6 using the storage array Huawei S5500T, when the storage array and the host are directly connected, the storage array host port can select a P2Pnetwork topology.
Correct Answer: B
Vote an answer
Which of the following scenarios is most suitable for enabling OceanStor V3 deduplication?
Correct Answer: B
Vote an answer
Which of the following is a description of theUltraPath multipath setting? (Multiple answers)
Correct Answer: A,B
Vote an answer
0
0
0
10